Operation
Nozzle goes upwards slowly from the bottom level of bottle towards neck during filling to minimize forming adjustable nozzle is reciprocating according to filling dose. The dosing block with a hexagonal bolt,this means different fill size can be set easily within minimum of time. The main drive consists of a helical gearbox driven by A/c motor & through controlled by an Ac frequency drive. The speed can be set in terms of bottles per minute. The conveyor drive consists of a hallow shaft, geared motor controlled by an Ac frequency drive. A knob can set the speed of conveyor.
Technical Specification
Out/Put |
Up to 20 BPM (Depending on bottle size) |
|
Filling Range |
10 ml to 1000 ml (with help of change parts) |
|
Direction of Movement |
Left to Right |
|
Number of head/syringe |
4 head |
|
Electrical |
Main Machine |
2.0 HP / 415 Volts / 50 Hz. |
Conveyor |
1.0 HP / 415 Volts / 50 Hz. |
|
Height of Conveyor |
860 mm to 910 mm adjustable. |
|
Net Weight |
600 Kgs. |
|
Change parts required |
(A) Syringes. (B) Nozzle (C) Inlet & outlet hose pipe |
Salient Features